Home / Products / Lightning Arrester / Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester
Lightning Arrester

Lightning Arrester

Zinc oxide arrester is a lightning protection device with superior protection performance, light weight, pollution resistance and stable performance. It mainly uses the good nonlinear volt-ampere characteristics of zinc oxide to make the current flowing through the arrester extremely small (microampere or milliampere level) at normal working voltage; when overvoltage acts, the resistance drops sharply, discharging the overvoltage energy to achieve the protection effect. The difference between this arrester and the traditional arrester is that it has no discharge gap, and uses the nonlinear characteristics of zinc oxide to play the role of current discharge and breaking.


Color: red, brown, gray or customer requirements;

Share:

Product Detail

ZheXi Electric Power Technology Co., Ltd., as a leading Zinc Oxide Arrester Manufacturer, offers a state‑of‑the‑art ZnO Gapless Surge Arrester engineered for superior lightning protection in electrical systems. This gap‑free design employs zinc oxide's nonlinear volt‑ampere characteristics to maintain microampere/milliampere currents under normal voltages and sharply reduce resistance during overvoltage events for rapid surge energy discharge. Unlike traditional arresters with discharge gaps, ZheXi's ZnO Gapless Surge Arrester enhances reliability and longevity by eliminating mechanical spark gaps subject to wear.


Available in standard red, brown, and gray hues—or custom colors—each unit features pollution‑resistant materials, lightweight construction, and consistent operation across diverse environments.


Services & Custom Solutions



Key Features


Gapless Design

Nonlinear Energy Absorption

Robust Construction

Lightweight & Compact


Advantages



Applications


ZheXi's surge arresters protect critical infrastructure, including:



For personalized recommendations or pricing details—whether you're evaluating transformer lightning arrester price options or exploring Metal Oxide Lightig Arrester Wholesale opportunities—consult the ZheXi team today to leverage the expertise and trustworthiness of every unit from this Zinc Oxide Arrester Manufacturer.

Lightning Arrester

Product Parameters

ModelRated voltage Continuous operating voltageDC reference voltageResidual voltageMaximum leakage current under 0.75 U1m4Nominal discharge current Creepage distanceWeight
Under lightning impulse currentUnder the impact of steep wave currentUnder the operation of impulse current
kVkVkVμAKAmm/kvkg
HY5WZ- 17/451713.6244551.838.3505312
HY5WS-17/501713.6255057.542.5505312
HY5WZ-51/1345140.8731141341545053110
HY10W-102/26610279.614826629722650103137
HY10W-108/2811088415728131523950103137
HY10W-204/53220415929653259445250103190
HY10W-216/562216168.531456263047850103190
Order information:
① Rated voltage;
② Residual voltage under lightning impulse current;
③ Nominal discharge current;
④ Creepage distance
Ps. Different designs can be provided according to customer requirements

How To Choose, Install & Maintain

Selection Guide


When choosing a Zinc Oxide Arrester Manufacturer's model (e.g., HY5WZ‑17/45, HY10W‑204/532), consider:


  • Rated Voltage (e.g., 17 kV, 204 kV) matching your system specifications.

  • Residual Voltage compatibility with protected equipment thresholds.

  • Nominal Discharge Current (5 kA, 10 kA) based on expected surge risks.

  • Creepage Distance (e.g., 50 mm/kV) for polluted or coastal environments.

  • Environmental Conditions, such as altitude, humidity, and pollution levels.


Installation & Maintenance Advice


Installation

  • Follow IEC/local standards; mount vertically and secure to robust grounding systems.

  • Avoid mechanical stress and ensure proper torque on all connections.


Maintenance

  • Conduct Regular Inspections for cracks, corrosion, and pollutant buildup.

  • Monitor Leakage Current with diagnostic tools to detect early aging.

  • Perform Post‑Surge Checks: replace arresters after severe lightning events.


Lightning Arrester

Production Process and Details

1. Cutting materials

1. Cutting materials

2. Pressurized vulcanization

2. Pressurized vulcanization

3. Vulcanization molding

3. Vulcanization molding

4. Surface treatment

4. Surface treatment

5. Assembly

5. Assembly

6. Testing

6. Testing

7. Packaging

7. Packaging

FAQ

Q

A

Can we print our trademark or company name on your product or package?

OEM and ODM orders are warmly welcomed, we have rich successful experience in OEM projects. In addition, our R&D team will provide you with professional suggestions.

Q

A

How does your company do in terms of quality control?

1) We choose all raw materials to be of high quality.

2) Professional and skilled workers pay attention to every detail in handling the production process.

3) The quality control department is specialized in quality inspection for each process.

Q

A

How can I get samples to test your quality?

We can provide free samples for you to test and check, just bear the freight cost.

Contact us to know more about our products, our professional team will serve you and customize it according to your requirements.

Can't find what you were looking for?

Need a Custom Solution?

CONTACT US
WeChat